Requirements
You will need a PC or a PG with a CD-ROM drive. You will also need a full keyboard on the
PCU. The supplied CD-ROM containing the system software is also required for installation.
This method must be used if your PC/PG only has partitions with a FAT32 data file structure.
Transfer
The parallel interface for the HMI software installation must be used for the transfer.
Operator action
1. Copy INTERLNK.EXE from the HMI directory on the CD to WINDOWS\COMMAND on
2. Switch off the PCU.
3. Using the parallel connecting cable (PC-Link cable, LapLink cable), connect the parallel
4. Switch on PCU.
5. Select the "Service menu" in the Boot Manager. [hidden menu entry].
6. Press key <8>: Start PC Link
7. Enter one of the passwords for authorization levels 0 - 2.
8. Now copy the entire contents of the HMI Advanced directory on the CD to the
9. On completion of the transfer, close INTERSVR on the PCU by pressing <ALT> + F4.
10. The system boots after the PCU has restarted.
PCU Basesoftware (IM6)
Commissioning Manual, 10/2006, 6FC5397-0DP10-0BA0
the PC/PG. Insert the following line in CONFIG.SYS:
device=c:\windows\command\interlnk.exe /AUTO
port LPT on the PC to port LPT on the PCU.
The main menu is displayed:
The system prompts you to enter a password:
D:\INSTALL directory on the PCU.
The computer is then restarted.
The installation now proceeds automatically with the PCU's InstallShield. You can
operate the InstallShield prompt dialogs with TAB and the cursor keys (TAB corresponds
to the END key on the OP0xx).
Installing software and network operation
3.1 Installing software and software update
3-7