Configuration For Exiting The Hmi - Siemens SINUMERIK 810D Commissioning Manual

Hide thumbs Also See for SINUMERIK 810D:
Table of Contents

Advertisement

2.4.3

Configuration for exiting the HMI

HMI monitoring
Exiting of the HMI advanced is monitored by a separate application, hmiexit.exe. This
application is started implicitly via the shutdown.bat batch file. In case of error, the
application forces the operating system to shut down. An error occurs if the HMI cannot be
exited within the configured delay.
Optionally, the parameters below can be set for hmiexit in file: E:\SITOP\hmiexit.ini.
[Actions]
#Waiting time in seconds for closing HMI Advanced applications
Wait = 120
# Action on expiration of the waiting time
ForceShutdown = True
These default settings only need to be changed if it takes longer than 120 seconds to exit the
HMI applications in an OEM installation. This configuration is not usually changed.
Configuring the EXIT button
During production, the option to shut down the HMI via the EXIT button in the operating area
menu should be disabled, as this function cannot be synchronized with the UPS module.
The EXIT button is disabled by entering ExitButton=False in the Regie.ini file.
Hibernate
The operating system's hibernate mode is suspended when operating the UPS, as the USB
interface always has to be active for the UPS module.
Note
More information can be found in the product descriptions with the corresponding order
number.
PCU Basesoftware (IM6)
Commissioning Manual, 10/2006, 6FC5397-0DP10-0BA0
Configuring the system
2.4 PCU with SITOP UPS module
2-23