boards.fm
Boards for HiPath 3000
Peripheral Boards
3.3.10
SLA8N (not for U.S.), SLA16N, SLA24N
Introduction
The peripheral boards
SLA8N (Subscriber Line Analog) with eight analog T/R interfaces (not for U.S.)
●
SLA16N (16 analog interfaces)
●
SLA24N (24 analog interfaces)
●
can be used in HiPath 3750, HiPath 3550 and HiPath 3700.
Switches and LEDs
LEDs
Figure 3-61
SLA8N (not for U.S.), SLA16N, SLA24N (S30810-Q2929-X200, -X100, -X)
The operating mode (short or long line with the appropriate flash times) can be set up for each
subscriber line interface with HiPath 3000 Manager E (the menu Settings: Set up station –>
Station –> Parameters –> Flags).
3-132
H1 (green)
H2 (red)
Lockout switch S1
(position = free, factory default)
P31003-H3550-S403-4-7620, 02/05