Table of Contents

Advertisement

Code
Detection description
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Check the connection of connectors between the Main
Communication error
Controller Board (J601, J602) and the FAX-NCU Board
with CCU/modem, or no
E736
0000
(J1201, J1204).
FAX board installed on
(2) Replace the connectors between the Main Controller
FAX model.
Board (J601, J602) and the FAX-NCU Board (J1201,
J1204).
(3) Replace the FAX-NCU Board.
(4) Replace the Main Controller Board.
When the same error repeatedly occurs after several
Error detection on either
times of turning the power OFF/ON, execute the following
E740
0002
Network Board or Mac
remedies.
address
(1) Check the connection of the network cable.
(2) Replace the Main Controller Board.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
0002 Language file error
remedies.
Update the set of the Controller Firmware
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
Engine ID error (Invalid
remedies.
4000
engine connection is
E744
(1) Check the DC Controller Board.
detected)
(2) Update the Engine Firmware.
(3) Update the set of the Controller Firmware
When the same error repeatedly occurs after several
Communication error
times of turning the power OFF/ON, execute the following
6000
with Wireless LAN
remedies.
board.
(1) Replace the Wireless LAN Board.
(4) Replace the Main Controller Board.
When the same error repeatedly occurs after several
Fan Motor cannot rotate
times of turning the power OFF/ON, execute the following
E806
0000
at specified revolution
remedies.
speed.
(1) Replace the Main Fan Unit.
(2) Replace the DC Controller Board.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
Fixing Assembly_Edge
E808
0001
remedies.
Left Cooling Fan error
(1) Replace the Edge Left Cooling Fan.
(2) Replace the DC Controller Board.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
Fixing Assembly_Edge
E808
0002
remedies.
Right Cooling Fan error
(1) Replace the Edge Right Cooling Fan.
(2) Replace the DC Controller Board.
7
Error Codes > Jam Codes
Remedy
T-7-2
7
Error Codes > Jam Codes

Jam Codes

Jam Codes
Cause
Scanner Jam Codes
0001H
Non-DES sensors.
0002H
DES Sensor Stationary
0094H
Initial Stationary
0095H
Pickup NG
0071H
Timing error
Printer Jam Codes
0004H
Re-pickup Delay Jam
0005H
Multi-purpose tray pickup delay jam
0008H
Pickup Stationary Jam
000CH
Fixing Delivery Delay Jam
0010H
Fixing Delivery Stationary Jam
0014H
Internal Paper Jam
0018H
Door Open Jam
001CH
Wrap Jam
0020H
Reversal Delay Jam
0021H
Reversal Stationary Jam
7-4
T-7-3
7-4

Advertisement

Table of Contents
loading

Table of Contents