COMMUNICTION PARAMETER(Parameter P35 to P40)
Used to set the parameters necessary for communication.
Parameter
Function name
No.
Communication
P35
station No. setting
P36
Communication speed
P37
Stop bit
P38
Parity check
P39
Timeover detect (s)
Send wait time (ms)
P40
Note1) The power supply must be turned off after setting the data for the communication
parameters P35 to P40. The set values will be effective afer the power supply is
turned on again.
Note2) If the hold time for information exchange disabled state exceeds the permitted
time when operation command select(parameter P08) and frequency setting
signal (parameter P09) is being set for communication, the inverter will fault stop
(OP display). The permitted time can be set with timeover detect (parameter P90).
P REGION PASSWORD(Parameter 41)
A password can be set to prevent unintentional changes to the parameter
data after they have been set.
Parameter P41: Sets passwords for the parameters in all regions(P region and d region).
Data setting range 000
[Procedures for changing parameter
data after setting password]
Example when password is set to "777" for parameter P41.
STOP
Press the STOP button to stop the inverter.
When the MODE button is pressed five times,
MODE
the password input display(P.PS) will appear, and
the main display will flicker.
Press the
the previously set password.
(The main display will flicker.)
The parameter No. will appear when the SET button
SET
is pressed.
( Example: When the previous parameter No. is "P01".)
After this step, the data is changed with the normal changing procedures.
Note) After the password is set, the "function setting mode" cannot appear without
inputing the password.(Write down the password so that you do not forget it.)
54
1 to 31
48
4800bps/96
1:1bit / 2:2bit
0: No parity/ 1: Odd parity/ 2: Even parity
.
000
0.1 to 60( "000" is the setting not to
perform the time-over detect.)
1 to 999
.
1 to 999( "000" indicates that there is no password.)
(up) and
(down) buttons to display
Data setting value and details
9600bps/192
19200bps
Main display
0
0
0
P.
P
S
7
7
7
P
0
1