Communication Function

The following functions are available depending on communications.
Register No.
Function
Relay No.
DT129
DT130
DT131
DT132
DT133
DT134
DT135
DT136
Monitor
DT137
DT138
DT139
DT140
DT141
DT142
DT143
R144
R145
R146
R147
DT237
DT238
Control/
R250
Command
DT253
DT255
DT0
Setting
(Parameter No.)
Note1) " " suffixed to the relay number means the specified position for BIT
(hexadecimal 0 to F). For the details on the functions of each BIT, refer
to each functional descriptions.
Note ) Rrefer to the next page for the explanation of the data type mentioned in
the above table.
Function name
Output frequency
Output current
Output voltage
Internal DC voltage 0.1V DC unit
Setting frequency
Detection frequency 0.01Hz unit
Door position area
Door position
OPEN arrival position data 1unit
No. of door switching 1time
Encoder detection status
Fault details 1 (latest)
Fault details 2 (second to latest)
Fault details 3 (third to latest)
Fault details 4 (fourth to latest)
Control input terminal state Contact data
Control output terminal state Contact data
Operation status
Operation control status Contact data
Without memory
Frequency
setting
With memory
Operation control
Fault reset command 0x9696
Emergency stop command 0x9696
Parameter setting
Remarks
0.01Hz unit
0.1A unit
0.1V AC unit
0.01Hz unit
0 : OPEN arrival
7 : CLOSE arrival 8-13 : CLOSE operation
1unit
0.01kHz unit
+ : FWD
- : REV
Refer to the next page for the contents
of the data.
Contact data
0.01Hz unit
Contact data
P region : Register No. = Parameter No.
d region : Register No.= Parameter No.+256
(data type 3)
(data type 2)
(data type 2)
(data type 2)
(data type 3)
(data type 3)
1-6 : OPEN operation
(data type 1)
(data type 1)
(data type 1)
(data type 3)
(data type 3)
79