Arrival position and speed change position (Parameter d02 to d13)

The arrival position and speed change position can be set with a percent to using
the door width setting value (Parameter d01) as 100%.

Setting change of OPEN/CLOSE arrival position (Parameter d02 and d08)

In case of no arrival signal, movable range of the door and door width measurement
value is the same. Therefore, setting value of OPEN/CLOSE arrival position is required
to be changed and arrival area width is required to be set.
If there is no arrival area width, the door position data will not conform to arrival area in
normal operation. To secure the arrival area, the setting of OPEN/CLOSE arrival position
shall be changed.
Parameter d02 (CLOSE arrival position): Increase the setting value
(Example: If 5% is set, "5
Parameter d08 (OPEN arrival position): Decrease the setting value
(Example: If 95% is set, "100

Arrival hold frequency (Parameter d14 and d21)

Set the OPEN/CLOSE arrival hold operation frequency .
Note) If the arrival hold frequency is too high, an overcurrent fault, overload fault
or motor overheating could occur or the noise could increase or the door
could be damaged.
Frequency (Parameter d15 to d20 and d22 to d27)
The frequency of OPEN operation mode and CLOSE operation mode should be set.

Acceleration and deceleration time (d28 to d39)

While setting the acceleration/deceleration time, set the time from 0.5Hz to Max.
output frequency.
If input CLOSE signal in OPEN operation or input OPEN signal in CLOSE operation,
the speed is controlled according to the first acceleration time (Parameter P01) or
the first deceleration time (Parameter P02).
Hold current (d40 and d41)
Used to set the hold capacity parameter in OPEN/CLOSE hold operation with the
current level.
Note) If the hold current level is too high, an overcurrent fault, overload fault or motor
overheating could occur or the noise could increase.
Note) The motor current will increase when the hold current level is increased.
Carefully consider the settings of the electronic thermal select and current
setting (Parameter P06 and 07).
Stop time of OPEN/CLOSE hold operation (d42)
In the OPEN hold area and CLOSE hold area, the inverter will continue to operate
(hold operation), even the OPEN signal and CLOSE signal are both turned OFF.
Set time with this parameter, if stop operation (hold operation) is required,
Data setting = "0" : (Hold operation) continue to operate (does not stop).
Data setting = " 0.1 to 999 (s)" : Stop operating at the setting time.
Arrival hold wait frequency and arrival hold wait time (Parameter d43 to d46)
After the arrival signal is turned on ON, the hold wait operation can be carried out.
Once the hold wait operation is over, it changes to hold operation.
Used to set the frequency and time of the hold wait operation with this parameter.
Start timer and deceleration timer (Parameter d47 to d50)
In the SW operation mode, arrival signal and speed change signal as well as
start timer and deceleration timer can be used to set the operation mode.
0
5 " is the arrival area width.)
95
5 " is the arrival area width.)
67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents