ELEC
1
È
É
L/B
É
Control system
B/O
L/B
UP
B/O
Slant detection switch
1. Measure:
• Slant detection switch input voltage
Out of specification → Check the wiring
harness.
Measurement steps:
1. Disconnect the slant detection switch cou-
pler 1.
2. Push the unlock button, and then measure
the input voltage at the slant detection
switch coupler (wiring harness end).
Slant detection switch input voltage
(reference data):
Blue/black (L/B) –
Black/orange (B/O)
4.75–5.25 V
2. Check:
• Slant detection switch continuity
Out of specification → Replace the slant
detection switch.
Checking steps:
É
1. Remove the slant detection switch.
Refer to "Electrical box disassembly."
2. Check the slant detection switch continu-
ity.
NOTE:
Be sure to turn the switch over to both the left
and right as shown.
Slant detection switch continuity:
Position
Normal
position È
Overturned É
7-37
E
Blue/black (L/B) –
Black/orange (B/O)
No continuity
Continuity