Accessories

8.1

DRIVE-CLiQ cabinet gland

8.1
8.1.1

Description

The DRIVE-CLiQ cabinet gland is used to connect two DRIVE-CLiQ cables and can be
installed in a cabinet panel.
At the interface outside the cabinet, a DRIVE-CLiQ connection is implemented with degree
of protection IP67 acc. to EN 60529; however, on the other hand inside the cabinet, a
connection with degree of protection IP20 or IPXXB acc. to EN 60529. The interface
between the cabinet panel and DRIVE-CLiQ cabinet gland should have degree of protection
IP54 acc. to EN 60529.
In addition to the data lines, the power supply contacts of DRIVE-CLiQ are also routed via
the coupling.
8.1.2

Safety Information

Note
Only Siemens cables should be used for DRIVE-CLiQ connections.
Equipment Manual AC Drive
Manual, (GH6), 03/2006 Edition, 6SL3097-2AL00-0BP0