Siemens SINAMICS S120 Equipment Manual page 96

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Power Modules
3.1 Power Modules Blocksize (PM340)
Order
Line
No.
voltage
current
6SL3210
-
1SE23-
2UA0
1SE23-
8UA0
1SE24-
5UA0
1SE26-
0UA0
1SE27-
5UA0
1SE31-
0UA0
1SE31-
1UA0
1SE31-
5UA0
1SE31-
8UA0
Overload capability
Figure 3-20
3-38
Rated
Power
output
(high
overload)
A
[kW]
4 kHz
32
15.0
32.0
38
18.5
38.0
45
22.0
45.0
60
30.0
62.0
75
37.0
75.0
90
45.0
90.0
110
55.0
110.0
145
75.0
145.0
178
15.0
32.0
Load cycle with pre-load condition
Output current in A at a switching frequency of:
6 kHz
8 kHz
10 kHz
70%
30.4
28.8
25.6
34.2
30.4
26.6
40.5
36.0
31.5
58.9
55.8
49.6
67.5
60.0
52.5
76.5
63.0
51.8
93.5
77.0
63.3
112.4
79.8
68.9
30.4
28.8
25.6
Manual, (GH6), 03/2006 Edition, 6SL3097-2AL00-0BP0
12 kHz
14 kHz
16 kHz
50%
40%
22.4
19.2
16.0
22.8
19.0
15.2
27.0
22.5
18.0
43.4
37.2
31.0
45.0
37.5
30.0
40.5
33.8
27.0
49.5
41.3
33.0
58.0
50.8
43.5
22.4
19.2
16.0
Equipment Manual AC Drive