Husqvarna DXR250 Operator's Manual page 46

Demolition robots
Hide thumbs Also See for DXR250:
Table of Contents

Advertisement

Max-/min current
Max./min. current indicates the current interval that controls the prop. valve. A too high minimum value means that the
valve opens rapidly. This might mean that it is not possible to employ a function gently.
A low minimum value will increase the deadband of the control lever around the central position.
A low maximum value means that the valve does not open entirely and that the function cannot be run at maximum
speed.
A high maximum value means that the valve's maximum opening position is achieved more rapidly. This will impair
resolution of the movement.
Boom pressure
The Boom pressure can be decreased from the maximum 200 bar to 150 bar. The pressure changes with 5 bar intervals.
Machine types
Indicates which machine type the remote control is linked to. This setting must be made when updating the software or
replacing the control module etc. Press the selection key to confirm the choice.
Languages
Setting for which language should be shown in the display. Press the selection key to confirm the choice.
To return to the factory default language, english. Keep the selection key for Work mode button while turning the main
switch until you see the main menu.
Joystick setup
Settings to adjust thumb switch behavior.
OFF - sets thumb switch inactive.
Auto - if Extra 1 is active, right thumb switch will control it. Otherwise it will have the same function as the top switch.
If Extra 2 is active, left thumb switch will control it. Otherwise it will have the same function as the top button.
Extra 1/Extra 2 - The thumb switch will only control Extra 1/Extra 2. If extra function is deactivated, the thumb switch
will be deactivated.
Tool - (only valid for left joystick) - Thumb switch on left joystick will control the tool function.
Joysticks
Settings for adjusting the function of the control levers.
Deadband
Deadband indicates the position in which the joysticks start to be activated. The higher the value the farther out from
neutral position that the joysticks are activated.
Precision
Settings to adjust the precision.
Default precision - standard setting.
Enhanced precision at high speed - typically used when a high and even speed is essential through out the entire
joystick movement, e.g. when digging.
Enhanced precision at low speed - typically used when high precision at low speed is essential e.g. when working
with precision tools such as Grappler or Steel Shear (MG 100/200 or DSS200).