4-1. Compact 4-way Cassette Type

No.
1
Fan motor (for indoor)
2
Thermo. sensor (TA-sensor)
3
Heat exchanger sensor (TCJ-sensor)
4
Heat exchanger sensor (TC-sensor)
5
Float switch
6
Drain pump motor

4-2. Concealed Duct Type

No.
1
Fan motor (SM804BT)
Fan motor
2
(SM564BT/SM1104BT/SM1404BT)
3
Thermo. sensor (TA-sensor)
4
Heat exchanger sensor (TCJ-sensor)
5
Heat exchanger sensor (TC-sensor)
6
Float switch
7
Drain pump motor
8
Reactor

4-3. Ceiling Type

No.
1
Fan motor (SM564CT)
2
Fan motor (SM804CT)
3
Fan motor (SM1104CT/SM1404CT)
4
Thermo. sensor (TA-sensor)
5
Heat exchanger sensor (TCJ-sensor)
6
Heat exchanger sensor (TC-sensor)
7
Louver motor
8
Reactor
AMP Air Conditioning

4. SPECIFICATIONS OF ELECTRICAL PARTS

Parts name
Parts name
Parts name
Type
SWF-230-60-1R
Output (Rated) 60 W, 220–240 V
155 mm
10 kΩ at 25°C
Ø6 mm, 1200 mm
10 kΩ at 25°C
Ø6 mm, 1200 mm
10 kΩ at 25°C
FS-0218-102
ADP-1409
Type
ICF-280-120-1C
Output (Rated) 120 W, 220–240 V
ICF-280-120-2C
Output (Rated) 120 W, 220–240 V
618 mm
10 kΩ at 25°C
Ø6 mm, 1200 mm
10 kΩ at 25°C
Ø6 mm, 1200 mm
10 kΩ at 25°C
FS-0218-102
ADP-1409
CH-43-2Z-T
10 mH, 1 A
Type
SWF-280-60-1R
Output (Rated) 60 W, 220–240 V
SWF-280-60-2R
Output (Rated) 60 W, 220–240 V
SWF-280-120-2R
Output (Rated) 120 W, 220–240 V
155 mm
10 kΩ at 25°C
Ø6 mm, 1200 mm
10 kΩ at 25°C
Ø6 mm, 1200 mm
10 kΩ at 25°C
MP24Z2N
DC 15V
CH-43-2Z-T
10 mH, 1 A
– 23 –