Installing The Target System Probe - HP H8/3003 User Manual

Emulator terminal interface
Table of Contents

Advertisement

Installing the
Target System
Probe
Caution
3-2 In-Circuit Emulation
The following precautions should be taken while using the H8/3003
emulator. Damage to the emulator circuitry may result if these
precautions are not observed.
Power Down Target System. Turn off power to the user target system
and to the H8/3003 emulator before attaching and detaching the QFP
adaptor to the emulator or target system to avoid circuit damage
resulting from voltage transients or mis-insertion of the QFP board.
Verify User Plug Orientation. Make certain that Pin 1 of the QFP
socket/adaptor and Pin 1 of the QFP adaptor are properly aligned
before inserting the QFP adaptor the QFP socket/adaptor. Failure to do
so may result in damage to the emulator circuitry.
Protect Against Static Discharge. The H8/3003 emulator and the QFP
adaptor contain devices which are susceptible to damage by static
discharge. Therefore, operators should take precautionary measures
before handling the user plug to avoid emulator damage.
Compatibility of VOLTAGE/CURRENCY. Please be sure to check
that the voltage/currency of the emulator and target system being
connected are compatible. If there is a discrepancy, damage may result.
Protect Target System CMOS Components. If your target system
includes any CMOS components, turn on the target system first, then
turn on the H8/3003 emulator; when powering down, turn off the
emulator first, then turn off power to the target system.