Chapter 7
Power Control Setup
7.2

Connection Setup for Power Synchronized Unit

7.2
Connection Setup for Power Synchronized Unit
Refer to "Configuration Guide (Power Synchronized Unit)" for the required settings to use power control by
connecting power synchronized units to an ETERNUS AF.
7.3

Wake On LAN Settings

A network environment needs to be set to receive magic packets that are used by Wake On LAN for the ETER-
NUS AF.
The procedure to set Wake On LAN is as follows:
1
On the navigation of the ETERNUS Web GUI screen, click [System].
The [System] screen appears.
2
In [Category], click [Network].
The [Network] screen appears.
3
In [Action], click [Setup Network].
The [Setup Network Environment] screen appears.
4
In the [Setup Network Environment] screen, select [Enable] for [Wake on LAN].
For operations with cluster connections, set the IP address of the Slave CM for the "Slave IP Address"
of the MNT port.
To control power supply with servers in a network to which the ETERNUS AF does not belong, set
"Gateway" and specify the server IP address or the network address in "Allowable IP Address".
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
107
P3AG-1832-04ENZ0