Additional information
If the following error codes appear on the screen, check the corresponding items in the table.
Code
Message
SD04
Powering off. Internal temperature is too high.
Check temperature around the display.
SD05
Internal protection circuits turning power OFF.
Possible short in the speaker cable.
SD11
Powering off. Internal temperature is too high.
Check temperature around TV.
Signal names for 15-pin mini D-sub connecter
Pin No. Signal name
1
R
2
G
3
B
4
Not connected
5
Not connected
6
GND (ground)
7
GND (ground)
8
GND (ground)
Check
Check if the ambient temperature of the flat screen TV is high.
Check the speaker cable connections between the flat screen TV and the
speakers.
Check if the ambient temperature of the flat screen TV is high.
Pin No. Signal name
9
+5 V
10
GND (ground)
11
Not connected
12
SDA
13
HD
14
VD
15
SCL
15
77