Sinusoidal interference
The following table shows the EMC behavior of the modules with respect to sinusoidal
interference.
The table applies to the HMI device, docking station and power supply.
Sinusoidal interference
HF radiation (in electromagnetic
fields) in accordance with
IEC 61000-4-3
RF interference current on
cables and cable shielding
conforming to IEC 61000-4-6
Emission of radio interference
The following table shows the interference emissions from electromagnetic fields in
accordance with EN 55016, Limit Value Class A, Group 1, measured at a distance of 10 m.
30 to 230 MHz
230 to 1 000 MHz
Note
Before you connect the HMI device to the public electrical network, ensure that it is
compliant with Limit Value Class B in accordance with EN 55022.
Wireless Teach Pendant F IWLAN V2
Operating Instructions, 08/2010, A5E02453837-01
Test values
80% amplitude modulation at 1 kHz
Up to 10 V/m in the 80 MHz to 1 GHz range
Up to 10 V/m in the 1.4 GHz to 2 GHz range
Up to 1 V/m in the 2 GHz to 2.7 GHz range
Test voltage 10 V, with 80% amplitude modulation
of 1 kHz in the 9 kHz to 80 MHz range
< 40 dB (V/m) quasi-peak
< 47 dB (V/m) quasi-peak
PRELIMINARY II
1.7.2010
Safety instructions and standards
2.8 Electromagnetic compatibility
Degree of
severity
3
3