Planning the use

3.6 Planning an installation location for RFID tags

3.6
Planning an installation location for RFID tags
Installation location for the RFID tag
Observe the following when selecting the RFID tag installation location:
● You will need at least one RFID tag for each machine operated in fail-safe mode with the
enabling button.
● The installation surface of the RFID tag must have a level foundation.
● The installation surface must be non-metallic.
When mounting on metallic base, a spacer is required.
● Select an installation location that is clearly visible for the signs of the RFID tags with an
associated ID.
Influence on communication
Note the following:
● The use of an MDS D100 directly on metal is not permitted.
Metal influences the field data and thus the communication.
● Flush installation of a MDS D100 in metal reduces the field data.
● Metallic objects must not reduce the effective range.
● A test is necessary in critical applications.
You can find more information in the manual "MOBY D, System Manual, Edition 11/2006".
Function of the RFID tag
The HMI device uses the RFID tag to log onto a machine within a protected area.
Effective range of the RFID tag
The radius of the effective range of an RFID tag is a maximum of 5 cm.