Description
1.4 Digital input / output
Digital input
Using the private MIB variable snMspsDigitalInputLevel, you can read out the status of the
digital input.
Note
If the digital output changes status, an entry is made in the event protocol table.
● OID of the private MIB variable snMspsDigitalInputLevel:
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).siemens(4329).industria
lComProducts(20).iComPlatforms(1).simaticNet(1).snMsps(1).snMspsCommon(1).snMspsDi
gitalIO(39).snMspsDigitalIOObjects(1).snMspsDigitalInputTable(2).snMspsDigitalInpu
tEntry(1).snMspsDigitalInputLevel(6)
● values of the MIB variable
– 1: Signal 0 at the digital input (DI)
– 2: Signal 1 at the digital input (DI)
MIB file
The MIB variables can be found in the file "SN-MSPS-DIGITAL-IO-MIB" that is part of the
private MIB file "scalance_m_msps.mib".