Csa Certification Record; Electric Data; Fm Approvals - ABB TZIDC Operating Instructions Manual

Digital positioner
Table of Contents

Advertisement

TZIDC DIGITAL POSITIONER | OI/TZIDC-EN REV. B

CSA Certification Record

Certificate
Certificate
Class 2258 04

Electric data

Model TZIDC, P/N V18345-x0x2x2xx0x Intelligent Positioner
For use in
Input rated
Output pressure
Intrinsically safe with entity parameters of:
Terminals 11 / 12
Terminals 81 / 82
Terminals 83 / 84
Terminals 31 / 32
Terminals 41 / 42 and 51 / 52
Terminals Limit 2 41 / 42
and Limit 1 51 / 52
When installed per installation Drawing No 901064:
Temperature Code
Max. Ambient temperature
Change from two to one column
1649904 (LR 20312)
PROCESS CONTROL EQUIPMENT –
Intrinsically Safe, Entity – For Hazardous
Locations
Class I, Div 1, Groups A, B, C and D;
Class II, Div 1, Groups E, F, and G,
Class III, Div 1, Enclosure Type 4X
30 V DC; max.4 to 20 mA
80 psi (Marine version)
U
= 30 V
C
= 6.6 nF
max
i
I
= 104 mA
L
max
U
= 30 V
C
= 3.7 nF
max
i
I
= 110 mA
L
max
U
= 30 V
C
= 3.7 nF
max
i
I
= 90 mA
L
max
U
= 30 V
C
= 6.6 nF
max
i
I
= 110 mA
L
max
U
= 30 V
C
= 3.7 nF
max
i
I
= 96 mA
L
max
U
= 15.5 V
C
max
i
I
= 52 mA
L
= 30 μH
max
i
Note
The 'x' in P/N denotes minor mechanical variations or
optional features.
Local communication interface LCI shall not be used in
hazardous location.
Each pair of conductors of each intrinsic safety circuit shall
be shielded.
See FM installation drawing No. 901064 for Details.

FM Approvals

TZIDC Positioner, Model V18345-a0b2c2de0f
IS/I,II,III/1/ABCDEFG/T4 Ta = 85 °C – 901064/7/4; Enity;
NI/I/2/ABCD/T4 Ta = 85 °C;
S/II,III/2/FG/T4 Ta =85 °C; Type 4X
Max Enity Parameters: Per Control Drawings
a
Case/mounting – 1, 2, 3, 4 or 9
b Input/communication port – 1 or 2
c
Output/safe protection – 1, 2, 4 or 5
d Option modules for analog or digital position feedback –
= 0 μH
i
0, 1, 3 or 5
P
= 1 W
e
Mechanical kit (proximity swiches) for digital position
i
feedback (option) – 0, 1 or 3
f
Design (varnish/coding) – 1 or 2
= 0 μH
i
P
= 1 W
i
See FM installation drawing No. 901064 for Details.
= 0 μH
i
P
= 1 W
i
= 0 μH
i
P
= 1 W
i
= 0 μH
i
P
= 1 W
i
= 20 nF
P
= 1 W
i
T4
85 °C
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents