IECEx Ex i

Ex marking
Marking
Type Examination Test Certificate
Type
Standards
Temperature Data
Temperature class
Ambient temperature Ta
T4
T6*
*
When using the 'Limit monitor' plug in module in temperature class T6, the
maximum permissible ambient temperature range is 40 to 35 °C.
Electrical Data
In 'intrinsically safe Ex ib IIC / Ex ia IIC' type of protection, only
for connection to a certified intrinsically safe circuit.
Current circuit (terminal)
Signal circuit
(+11 / 12)
Contact input
(+81 / 82)
Switch output
(+83 / 84)
Local communication
Only for connection to a programming device using
interface (LCI)
an ABB LCI adapter (Um
Ex ia IIC T6 or T4 Gb
Ex ib IIC T6 or T4 Gb
IECEx TUN 04.0015X
Intrinsic safety 'i'
IEC 60079-0:2011
IEC 60079-11:2011
TZIDC Ex ia IIC
TZIDC Ex ib IIC
40 to 85 °C
40 to 85 °C
40 to 40 °C*
40 to 40 °C
Electrical information (maximum values)
U
= 30 V
C
i
i
I
= 320 mA
L
= negligibly small
i
i
P
= 1.1 W
i
U
= 30 V
C
i
i
I
= 320 mA
L
= negligibly small
i
i
P
= 1.1 W
i
U
= 30 V
C
i
i
I
= 320 mA
L
= negligibly small
i
i
P
= 500 mW
i
30 V DC) outside the
hazardous area.
The following modules may be operated as an option:
Current circuit (terminal)
Plug-in module for limit
monitor
(+51 / 52)
(+41 / 42)
Plug-in module for
analog position
feedback
(+31 / 32)
Special conditions
For the 'Limit monitor with proximity switches' circuit,
measures outside of the device must be implemented to
prevent the rated voltage from being up-scaled by more than
40 % due to transient disturbances.
It is only permissible to connect, disconnect, and switch live
circuits during installation or maintenance, or for the
purpose of carrying out repairs. Note: It is considered very
unlikely that a hazardous atmosphere would be present in
Zone 2 at the same time that installation, maintenance or
repair work was being carried out.
Only non-flammable gases may be used for pneumatic power
supply.
= 6.6 nF
Only use suited cable entries that meet the requirements of
EN 60079-15.
= 4.2 nF
= 4.2 nF
Electrical information (maximum values)
U
= 30 V
Ci = 3.7 nF
i
I
= 320 mA
Li = negligibly small
i
P
= 250 mW
i
U
= 30 V
Ci = 6.6 nF
i
I
= 320 mA
Li = negligibly small
i
P
= 1.1 W
i