Siemens FEC920 User Manual page 149

Flow energy calculator
Hide thumbs Also See for FEC920:
Table of Contents

Advertisement

Parameter path
Instrument.User25.BatchControl
Instrument.User25.AckAlarms
Instrument.User25.DemandArchiving
Instrument.User25.LoginDisabled
Instrument.User25.Signing
Instrument.User25.Authorising
Instrument.User25.ArchiveInterval
Instrument.User25.LoopControl
Instrument.User25.ProgramMode
Instrument.User25.ProgramEdit
Instrument.User25.ProgramStore
Instrument.Security.CommsPass
Instrument.Security.DefaultConfig
Instrument.Security.EngineerAccess
Instrument.Security.EngineerPassword
Instrument.Security.Feature2Pass
Instrument.Security.Feature3Pass
Instrument.Security.FeaturePass
Instrument.Security.OEMEntry
Instrument.Security.OEMParamLists
Instrument.Security.OEMPass
Instrument.Security.OEMStatus
Instrument.Security.OperatorPassword
Instrument.Security.PassPhrase
Instrument.Security.SupervisorPassword
Lgc2.1.FallbackType
Lgc2.1.In1
Lgc2.1.In2
Lgc2.1.Invert
Lgc2.1.Oper
Lgc2.1.Out
Lgc2.1.OutputStatus
Lgc2.2.FallbackType
Lgc2.2.In1
Lgc2.2.In2
Lgc2.2.Invert
Lgc2.2.Oper
Lgc2.2.Out
Lgc2.2.OutputStatus
Lgc2.3.FallbackType
Lgc2.3.In1
Lgc2.3.In2
Lgc2.3.Invert
Lgc2.3.Oper
Lgc2.3.Out
Lgc2.3.OutputStatus
Lgc2.4.FallbackType
Lgc2.4.In1
Lgc2.4.In2
Lgc2.4.Invert
Lgc2.4.Oper
Lgc2.4.Out
Lgc2.4.OutputStatus
Lgc2.5.FallbackType
Lgc2.5.In1
Lgc2.5.In2
Lgc2.5.Invert
Lgc2.5.Oper
Lgc2.5.Out
Lgc2.5.OutputStatus
Lgc2.6.FallbackType
Lgc2.6.In1
September 18
FEC920: USER GUIDE
Description
Batch control permission
Acknowledge alarms permission
Demand archiving permission
Login disabled
Signing permission
Authorising permission
Archive interval permission
Loop control permission
Program mode permission
Program edit permission
Program store permission
1 = Password required for comms access
1 = set all parameters to factory settings
1 = Engineer access required
Engineer pass phrase (default 100)
Features2 pass code
Features3 pass code
Features pass code
OEM pass phrase entry
OEM Parameter Lists
OEM pass phrase
OEM status (0 = Unlocked; 1 = Locked)
Operator pass phrase (default = 100)
The parameter to be written to if comms security is enabled
Supervisor pass phrase (default = blank
Fallback Condition
0 = Output False; Status Bad.
1 = Output True; Status Bad
2 = Output False; Status Good.
3 = Output True; Status good
Input Value 1
Input Value 2
Sense of Input Values
0 = Neither input inverted
1 = Input 1 inverted
2 = Input 2 inverted
3 = Both inputs inverted
Logic Operation
0 = Off; 1 = AND; 2 = OR;
5 = Input 1 = Input 2
7 = Input 1 > Input 2
9 = Input 1
Input 2;
Output Value (0 = Off (false); 1 = On (true))
Output Status (0 = Good; 1 = Bad)
Fallback Condition (as Lgc2.1.FallbackType)
Input Value 1
Input Value 2
Sense of Input Value (as Lgc2.1.Invert)
Logic Operation (as Lgc2.1.Oper)
The result of the logic operation (as Lgc2.1.Out)
Output Status (0 = Good; 1 = Bad)
Fallback Condition (as Lgc2.1.FallbackType)
Input Value 1
Input Value 2
Sense of Input Value (as Lgc2.1.Invert)
Logic Operation (as Lgc2.1.Oper)
The result of the logic operation (as Lgc2.1.Out)
Output Status (0 = Good; 1 = Bad)
Fallback Condition (as Lgc2.1.FallbackType)
Input Value 1
Input Value 2
Sense of Input Value (as Lgc2.1.Invert)
Logic Operation (as Lgc2.1.Oper)
The result of the logic operation (as Lgc2.1.Out)
Output Status (0 = Good; 1 = Bad)
Fallback Condition (as Lgc2.1.FallbackType)
Input Value 1
Input Value 2
Sense of Input Value (as Lgc2.1.Invert)
Logic Operation (as Lgc2.1.Oper)
The result of the logic operation (as Lgc2.1.Out)
Output Status (0 = Good; 1 = Bad)
Fallback Condition (as Lgc2.1.FallbackType)
Input Value 1
A5E45696052A Rev-AA
Type
Hex
Dec
Resolution
bool
0514
1300
Not applicable
bool
0515
1301
Not applicable
bool
0516
1302
Not applicable
bool
0517
1303
Not applicable
bool
0518
1304
Not applicable
bool
0519
1305
Not applicable
bool
051a
1306
Not applicable
bool
051b
1307
Not applicable
bool
051c
1308
Not applicable
bool
051d
1309
Not applicable
bool
051e
1310
Not applicable
bool
10c1
4289
Not applicable
bool
10c2
4290
Not applicable
bool
10c0
4288
Not applicable
string_t
63d3
25555 Not applicable
int32
10c4
4292
Not applicable
int32
10c5
4293
Not applicable
int32
10c3
4291
Not applicable
string_t
6d61
28001 Not applicable
bool
10c7
4295
Not applicable
string_t
6d30
27952 Not applicable
bool
10c6
4294
Not applicable
string_t
6437
25655 Not applicable
string_t
4416
17430 Not applicable
string_t
6405
25605 Not applicable
uint8
2efb
12027 Not applicable
float32
2ef9
12025 0dp
float32
2efa
12026 0dp
uint8
2efc
12028 Not applicable
uint8
2ef8
12024 Not applicable
3 = XOR; 4 = 1 set/2 reset
6 = Input 1
Input 2
8 = Input 1< Input 2
10 = Input 1
Input 2
bool
2efd
12029 Not applicable
uint8
2efe
12030 Not applicable
uint8
2f02
12034 Not applicable
float32
2f00
12032 0dp
float32
2f01
12033 0dp
uint8
2f03
12035 Not applicable
uint8
2eff
12031 Not applicable
bool
2f04
12036 Not applicable
uint8
2f05
12037 Not applicable
uint8
2f09
12041 Not applicable
float32
2f07
12039 0dp
float32
2f08
12040 0dp
uint8
2f0a
12042 Not applicable
uint8
2f06
12038 Not applicable
bool
2f0b
12043 Not applicable
uint8
2f0c
12044 Not applicable
uint8
2f10
12048 Not applicable
float32
2f0e
12046 0dp
float32
2f0f
12047 0dp
uint8
2f11
12049 Not applicable
uint8
2f0d
12045 Not applicable
bool
2f12
12050 Not applicable
uint8
2f13
12051 Not applicable
uint8
2f17
12055 Not applicable
float32
2f15
12053 0dp
float32
2f16
12054 0dp
uint8
2f18
12056 Not applicable
uint8
2f14
12052 Not applicable
bool
2f19
12057 Not applicable
uint8
2f1a
12058 Not applicable
uint8
2f1e
12062 Not applicable
float32
2f1c
12060 0dp
Page 141

Advertisement

Table of Contents
loading

Table of Contents