DOWNLOADING
When the wiring editor is opened the current wiring and diagram layout is read from the instrument. No changes
are made to the instrument function block execution or wiring until the download button is pressed. Any changes
made using the operator interface after the editor is opened are lost on download.
When a block is dropped onto the diagram, instrument parameters are changed to make the parameters for that
block available. If changes are made and the editor is closed without saving them there is a delay while the
editor clears these parameters.
During download, the wiring is written to the instrument which then calculates the block execution order and
starts executing the blocks. The diagram layout including comments and monitors is then written into instrument
flash memory along with the current editor settings. When the editor is reopened, the diagram is shown
positioned as it was when it was last downloaded.
COLORS
Items on the diagram are colored as follows:
Red
Blue
Green
Magenta
Purple
Black
September 18
FEC920: USER GUIDE
Figure 123 Comment and Monitor appearance
Toggles parameter names on and off in the monitor box.
Deletes the current link from the monitor.
Moves the monitor to the Clipboard, ready to be pasted
elsewhere. Short cut = <Ctrl>+<X>.
Copies the monitor from the wiring diagram to the Clipboard,
ready to be pasted elsewhere. Short cut = <Ctrl>+<C>.
Copies a monitor from the Clipboard to the wiring diagram. Short
cut = <Ctrl>+<V>.
Marks the monitor for deletion at next download.
Undoes the Delete command if download has not taken place
since.
Moves the item to the 'top' layer of the diagram.
Moves the item to the 'bottom' layer of the diagram.
Shows parameter help for the item.
Items which totally or partially obscure other items and items which are totally or partially
obscured by other items. Wires that are connected to unalterable or non-available
parameters. Execution breaks.
Non-available parameters in function blocks.
Items added to the diagram since last download are shown as green dashed lines.
All selected items, or any item over which the cursor is hovering.
Red wires when being hovered over by the mouse cursor.
All items added to the diagram before the last download. Redundant execution breaks.
Monitor and comment text.
A5E45696052A Rev-AA
Figure 124 Monitor
context menu