Fuel System Maintenance; Draining Water From The Fuel Filter; Replacing The Fuel Filter/Water Separator - Toro Greensmaster 3420 TriFlex Operator's Manual

Traction unit, 04540-serial no. 403099001 and up
Hide thumbs Also See for Greensmaster 3420 TriFlex:
Table of Contents

Advertisement

Fuel System
Maintenance
Draining Water from the
Fuel Filter
Service Interval: Before each use or daily
1.
Park the machine on a level surface and shut
off the engine.
2.
Place a drain pan under the fuel filter.
3.
Open the drain plug on the fuel filter
approximately one turn and drain any
accumulated water
Figure 35
1. Fuel filter
4.
Tighten the plug after draining.
Note:
Because the accumulated water will be
mixed with diesel fuel, drain the fuel filter into a
suitable container and dispose of it properly.
(Figure
35).
2. Drain plug
Replacing the Fuel
Filter/Water Separator
Service Interval: Every 800 hours
1.
Close the fuel-shutoff valve
the fuel tank.
1. Fuel-shutoff valve
g014720
2.
Clean the area where the filter canister mounts
(Figure
37).
3.
Place a drain pan under the fuel filter.
4.
Open the filter drain plug
1. Fuel filter/water separator
canister
5.
Unscrew the filter canister and dispose of it
according to local regulations.
39
(Figure
36) below
Figure 36
(Figure
37).
Figure 37
2. Filter-drain plug
g014626
g014720

Hide quick links:

Advertisement

Table of Contents
loading