Access To Set Up Page - Hitachi HIDIC EH-150 Applications Manual

Programable controller; ethernet module(eh-eth)
Hide thumbs Also See for HIDIC EH-150:
Table of Contents

Advertisement

5.2.5

Access to set up page

When PLC is power on, STATUS LED turns on or flickers. You can access Web setup page at both
conditions. We recommend setup the I/O assignment on CPU at first.
In the case that it is done with I/O correctly
In the case that it is not done with I/O assignment
Caution
- You can access Web setup page without I/O assignment, but you can not use on-line connection of LADDER EDITOR
for Windows via Ethernet, and ASR connection data transmission without I/O assignment.
Open Web browser to access setup page. Input IP address of EH-ETH.
For instance, in the case the dip switch is set as table 5.2.5.1, temporary IP address is "192.168.0.4", In this
case, type
http://192.168.0.4/
displayed.
ON
Web browser Ethernet information
Trouble shoot
If the setup page does not appear with above mentioned procedure, "Proxy setting" on your browser is wrong.
Please see "10.1 Trouble shooting flow (2) Various kinds setting.
Chapter 5 Configuration and procedure for starting communication
ETHERNET
I.ERR
ERR STATUS
POW
Tx/Rx
Figure 5.2.5.1 STATUS LED condition
at address input box of Web browser. By this procedure, setup page will be
Table 5.2.5.1 Dip switch setting example
Bit No.
1
2
3
4
OFF OFF OFF OFF
setting mode
5-6
EH-ETH
Green illumination
Green flickering 0.5s
5
6
7
8
OFF OFF
ON
Temporary IP address lowest
byte

Advertisement

Table of Contents
loading

Table of Contents