User Setting - ABB 2600T Series Operating Instructions Manual

266 with profibus pa communication pressure transmitters
Hide thumbs Also See for 2600T Series:
Table of Contents

Advertisement

Analog Input 2 setting
(Applicable only for Differential Pressure Sensor types)
Damping
AI2_PV_FTIME
Output scale 0%
AI1_OUT_SCALE 0%
Output scale 100%
AI2_OUT_SCALE 100%
Output Scale Unit
AI2_OUT_SCALE Unit Code
Critical Alarm Low
AI2_LO_LO_LIM
Advisory Alarm Low
AI2_LO_LIM
Advisory Alarm High
AI2_HI_LIM
Critical Alarm High
AI2_HI_HI_LIM
Alarm Hysteresis
AI2_ALARM_HYS
Fail Safe Type
AI2_FSAFE_TYPE
Analog Input 3 setting
Damping
AI1_PV_FTIME
Output scale 0%
AI1_OUT_SCALE 0%
Output scale 100%
AI1_OUT_SCALE 100%
Output Scale Unit
AI1_OUT_SCALE Unit Code
Critical Limit Low
AI1_LO_LO_LIM
Advisory Limit Low
AI1_LO_LIM
Advisory Limit High
AI1_HI_LIM
Critical Limit High
AI1_HI_HI_LIM
Alarm Hysteresis
AI1_ALARM_HYS
Fail Safe Type
AI1_FSAFE_TYPE
All the configurable parameters listed above can be afterward
modified either via the optional LCD HMI, or via software
application tools using the ABB DTM 266 PdP PA or the EDD
drivers.
Data regarding flange type and material, O-ring materials, and
type of filling liquid is stored in the device.
40 OI/266/PB-EN Rev. E | 2600T Series Pressure transmitters
0 second
0.0
PTRB_STATIC_P_SENSOR_HI_LIM
MPa
AI1_OUT_SCALE 0%
– 10% of the SPAN
AI2_OUT_SCALE 100%
+ 10% of the SPAN
0.5% of the SPAN
Last Usable Out Value
0 second
0.0
PTRB_SENSOR_LIM_HI
Kpa
AI1_OUT_SCALE 0%
– 10% of the SPAN
AI1_OUT_SCALE 100%
+ 10% of the SPAN
0.5% of the SPAN
Last Usable Out Value

11.4 User setting

Generally the 2600T pressure transmitters are delivered pre-
configured as per purchase order request in order to measure
Pressure, Level, Flow or Volume.
For the device configuration it is necessary to know at least the
following process info as minimum:
TAG
Calibration Range/Scale and its engineering unit as range
of pressure to be measured in input
Linearization Type defining the type of linearization to be
applied at the pressure measured in input in order to
convert it to the output measure
Output Range/Scale and its engineering unit.
Pressure and Level measurement setting
Process Info
TAG
Calibration LRV 0%
Calibration URV 100%
Calibration Unit
PRTB_SECONDARY_VALUE_1_UNIT
Linearization Type
PRTB_LIN_TYPE
Output scale 0%
Output scale 100%
Output Scale Unit
Flow measurement setting
Process Info
TAG
Calibration LRV 0%
Calibration URV 100%
Calibration Unit
PRTB_SECONDARY_VALUE_1_UNIT
Linearization Type
PRTB_LIN_TYPE
Output scale 0%
Output scale 100%
Output Scale Unit
11 Commissioning
Device parameter to be configured
PB_TAG_DESC
PRTB_SCALE_IN 0%
PRTB_SCALE_IN 100%
Linear
AI1_OUT_SCALE 0%
AI1_PV_SCALE 0%
PRTB_SCALE_OUT 0%
AI1_OUT_SCALE 100%
AI1_PV_SCALE 100%
PRTB_SCALE_OUT 100%
AI1_OUT_SCALE Unit Code
PRTB_PRIMARY_VALUE_UNIT
Device parameter to be configured
PB_TAG_DESC
PRTB_SCALE_IN 0%
PRTB_SCALE_IN 100%
Square Root
SQRT 3° pow
SQRT 5° pow
Bidirectional Flow
AI1_OUT_SCALE 0%
AI1_PV_SCALE 0%
PRTB_SCALE_OUT 0%
AI1_OUT_SCALE 100%
AI1_PV_SCALE 100%
PRTB_SCALE_OUT 100%
AI1_OUT_SCALE Unit Code
PRTB_PRIMARY_VALUE_UNIT

Hide quick links: