2.11 Transport and storage

— After unpacking the pressure transmitter, check the device
for transport damage.
— Check the packaging material for accessories.
— During intermediate storage or transport, store the
pressure transmitter in the original packaging only.
For information on permissible ambient conditions for storage
and transport, see "Technical data". Although there is no limit
on the duration of storage, the warranty conditions stipulated
on the order acknowledgment from the supplier still apply.

2.12 Safety information for electrical installation

Electrical connections may only be established by authorized
specialist personnel in accordance with the electrical circuit
diagrams. The electrical connection information in the manual
must be observed; otherwise, the applicable protection type
may be affected. Ground the measurement system according
to requirements.
2.13 Safety information for inspection and
maintenance
Warning – Risk to persons.
protection against accidental contact when the housing cover is
open. There are electric circuits within the housing which are
dangerous if touched. Therefore, the auxiliary power must be
switched off before opening the housing cover.
Warning – Risk to persons
pressure and with aggressive media. Any process media released
may cause severe injuries. Depressurize the pipeline/tank before
opening the transmitter connection.
Corrective maintenance work may only be performed by trained
personnel.
— Before removing the device, depressurize it and any
adjacent lines or containers.
— Check whether hazardous materials have been used as
materials to be measured before opening the device.
Residual amounts of hazardous substances may still be
present in the device and could escape when the device is
opened.
— Within the scope of operator responsibility, check the
following as part of a regular inspection:
Pressure-bearing walls/lining of the pressure device
Measurement-related function
Leak-tightness
Wear (corrosion)
8 OI/266/PB-EN Rev. E | 2600T Series Pressure transmitters