7.2 MDS D100

Memory areas
Depending on the manufacturer of the transponder chip, the memory configuration of an ISO
transponder consists of varying sizes of user memory.
The typical sizes are 112 bytes, 256 bytes, 992 bytes EEPROM or 2000 bytes, 8192 bytes
FRAM. Each ISO transponder chip has an 8-byte long unique serial number (UID, read
only). This UID is transferred as an 8 byte value through a read command to address FFF0
with a length of 8.
Note
OPT memory
The transponders have an OTP memory. This was previously only supported by the RF300
readers.
7.2
MDS D100
7.2.1

Characteristics

MDS D100
188
Characteristics
Area of application
Memory size
Write/read range
Mounting on metal
ISO standard
Degree of protection
From simple identification such as electronic
barcode replacement/supplementation, through
warehouse and distribution logistics, right up to
product identification.
112 bytes of EEPROM user memory
See section Field data (Page 37).
Yes, with spacer
ISO 15693
IP68
System Manual, 07/2015, J31069-D0227-U001-A9-7618
SIMATIC RF200