Transponder
7.24 MDS D522
Mounting information for screws
You can screw the transponder into a pre-drilled threaded hole using the screw-in aid.
Mounting information for adhesion
● Drill installation hole
● The adhesive surfaces must be dry, free from dust, oil, stripping agents and other
impurities
● Apply adhesive according to the manufacturer's processing instructions
● Press in MDS D522 using your fingers; with antenna to the outside
● Remove residues of adhesive
● Allow to cure according to the manufacturer's instructions
● Flush-mounting of MDS D522 in metal with tools
7.24.4
Technical specifications
Table 7- 60
Product type designation
Memory
Memory configuration
•
•
Read cycles (at < 40 ℃)
Write cycles (at < 40 ℃)
Data retention time (at < 40 ℃)
Write/read distance (S
MTBF (Mean Time Between Failures)
Mechanical specifications
Housing
•
•
Recommended distance to metal
Power supply
282
Technical specifications for MDS D522
UID
User memory
)
g
Material
Color
SIMATIC MDS D522
8 bytes
•
8192 bytes FRAM
•
> 10
12
> 10
12
> 10 years
Dependent on the reader used, see section "Field
data (Page 37)"
2.5 x 10
hours
6
Plastic PA 6.6 GF; brass nickel plated
•
Black/silver
•
> 0 mm
Inductive, without battery
System Manual, 07/2015, J31069-D0227-U001-A9-7618
6GT2600-5AF00
SIMATIC RF200