Transponder
7.18 MDS D424
Flush-mounting
h
a
Figure 7-47
Note
If the minimum guide values (h) are not observed, a reduction of the field data results. It is
possible to mount the MDS with metal screws (M3 countersunk head screws). This has no
tangible impact on the range.
7.18.4
Technical specifications
Table 7- 46
Product type designation
Memory
Memory configuration
•
•
•
Read cycles (at < 40 ℃)
Write cycles (at < 40 ℃)
Data retention time (at < 40 ℃)
Write/read distance (S
260
≥ 15 mm
≥ 25 mm
Flush-mounting of the MDS D424 in metal with spacer
Technical specifications for the MDS D424
UID
User memory
OPT memory
)
g
SIMATIC MDS D424
8 bytes
•
2000 bytes FRAM
•
16 bytes FRAM
•
> 10
12
> 10
12
> 10 years
Dependent on the reader used, see section "Field
data (Page 37)"
System Manual, 07/2015, J31069-D0227-U001-A9-7618
6GT2600-4AC00
SIMATIC RF200