Transponder
7.8 MDS D160
Mechanical strength
•
•
•
Resistance to chemicals
MDS lifespan
Degree of protection
Shock-resistant to IEC 68-2-27
Vibration-resistant to IEC 68-2-6
Torsion and bending load
Design, dimensions and weight
Dimensions (Ø x H)
Weight
Type of mounting
The values for shock and vibration are maximum values and must not be applied continuously.
1
Note
Regeneration time between washing cycles
The regeneration time for the MDS D160 between washing cycles must be at least 24 hours.
218
Isostatic pressure
Axial pressure
Radial pressure
300 bar for 5 min
•
1000 N for 10 s
•
1000 N for 10 s
•
All chemicals normally used in the washing pro-
cess
At least 100 wash cycles
IP68
•
24 hours, 2 bar, +20 °C
IPx9K
•
40 g
1)
18 ms; 6 axes; 2000 repetitions/h
10 g
1)
10 to 2000 Hz; 3 axes; 2.5 h
Not permitted
16 x 3 mm
1.2 g
Patched
•
Sewn in
•
Glued
•
System Manual, 07/2015, J31069-D0227-U001-A9-7618
6GT2600-0AB10
SIMATIC RF200