7.13 MDS D339
Degree of protection to EN 60529
Shock-resistant to EN 60721-3-7 class 7M3
Vibration-resistant to EN 60721-3-7, class 7M3
Torsion and bending load
Design, dimensions and weight
Dimensions (Ø x H)
Weight
Type of mounting
The values for shock and vibration are maximum values and must not be applied continuously.
1
For mounting with the spacer (6GT2690-0AA00), use a stainless steel M5 screw to avoid damag-
2)
ing the MDS in high temperatures (expansion coefficient).
7.13.7

Use of the MDS D339 in hazardous areas

The MDS D339 mobile data memory is classed as a piece of simple, electrical equipment
and can be operated in Protection Zone 2, Device Group II, Category 3G.
The following requirements of the 94/9/EC directive are met:
● EN 60079-0:2006
● EN 60079-15:2005
● EN 61241-0:2006
● EN 61241-1:2004
238
IP68
2 hours, 2 bar, +20 °C
IPx9K
steam jet: 150 mm; 10 to 15 l/min; 100 bar; 75
°C
50 g
1)
20 g
1)
Not permitted
85 x 15 mm
50 g
1 x M5 screw
2)
1.5 Nm