Abbreviation
Explanation
STW
Control word
ZSW
Status word
NSOLL_A
Speed setpoint 16 bit
NSOLL_B
Speed setpoint 32 bit
NIST_A
Speed actual value 16 bit
NIST_B
Speed actual value 32 bit
IAIST
Current actual value
IAIST_GLATT Current actual value, smoothed
MIST_GLATT Torque actual value, smoothed
Interconnection of the process data
Image 3-1
Fieldbuses
Function Manual, 01/2016, FW V4.7 SP6, A5E34229197B AC
Interconnection of the send words
Communication via PROFIBUS and PROFINET
Abbreviation
Explanation
PIST_GLATT
Actual active power value, smoothed
M_LIM
Torque limit
FAULT_COD
Fault number
E
WARN_COD
Alarm number
E
MELD_NAMU
Control word according to the VIK-NAMUR
R
definition
G1_STW /
Control word for encoder 1 or encoder 2
G2_STW
G1_ZSW /
Status word for encoder 1 or encoder 2
G2_ZSW
G1_XIST1 /
Position actual value 1 from encoder 1 or
G2_XIST1
encoder 2
G1_XIST2 /
Position actual value 2 from encoder 1 or
G2_XIST2
encoder 2