Hitachi SJ700-2 Series Instruction Manual page 123

Easy-sequence programming software ezsq
Hide thumbs Also See for SJ700-2 Series:
Table of Contents

Advertisement

(3) B parameters
Display
Function name
code
Maximum-limit level of window
b066
comparators O2
Minimum-limit level of window
b067
comparators O2
Hysteresis width of window
b068
comparators O2
Operation level at O
b070
disconnection
Operation level at OI
b071
disconnection
Operation level at O2
b072
disconnection
Cumulative input power data
b078
clearance
Cumulative input power display
b079
gain setting
Start frequency adjustment
b082
Carrier frequency setting
b083
Initialization mode (parameters
b084
or trip history)
b085 Country code for initialization
Frequency scaling conversion
b086
factor
b087 STOP key enable
b088 Restart mode after FRS
Automatic carrier frequency
b089
reduction
b090 Dynamic braking usage ratio
b091 Stop mode selection
b092 Cooling fan control
b095 Dynamic braking control
b096 Dynamic braking activation level
Thermistor for thermal protection
b098
control
b099 Thermal protection level setting
b100 Free-setting V/f frequency (1)
b101 Free-setting V/f voltage (1)
b102 Free-setting V/f frequency (2)
b103 Free-setting V/f voltage (2)
b104 Free-setting V/f frequency (3)
b105 Free-setting V/f voltage (3)
b106 Free-setting V/f frequency (4)
b107 Free-setting V/f voltage (4)
b108 Free-setting V/f frequency (5)
b109 Free-setting V/f voltage (5)
b110 Free-setting V/f frequency (6)
b111 Free-setting V/f voltage (6)
b112 Free-setting V/f frequency (7)
b113 Free-setting V/f voltage (7)
b120 Brake Control Enable
b121 Brake Wait Time for Release
b122 Brake Wait Time for Acceleration 0 to 500
b123 Brake Wait Time for Stopping
b124 Brake Wait Time for Confirmation 0 to 500
Brake Release Frequency
b125
Setting
b126 Brake Release Current Setting
b127 Braking frequency
Range of setting
-100. to 100. (lower limit : b067 + b068 / 2)
-100. to 100. (lower limit : b066 - b068 / 2)
0 to 10. (lower limit : b066 - b067 / 2)
0 to 100 or "no" (ignore)
0 to 100 or "no" (ignore)
-100 to 100 or "no" (ignore)
Clearance by setting "01" and pressing the STR key
1 to 1000.
10 to 999
*5
0 (clearing the trip history), 1 (initializing the data),
2 (clearing the trip history and initializing the data)
0 (Japan), 1 (EU), 2 (U.S.A.)
1 to 990
0 (enabling), 1 (disabling),
2 (disabling only the function to stop)
0 (starting with 0 Hz), 1 (starting with matching
frequency), 2 (starting with active matching frequency)
0 (invalid), 1 (valid)
0 to 1000
0 (deceleration until stop), 1 (free-run stop)
0 (always operating the fan), 1 (operating the fan only
during inverter operation [including 5 minutes after
power-on and power-off])
0 (disabling), 1 (enabling [disabling while the motor is
topped]), 2 (enabling [enabling also while the motor is
topped])
200V class: 330 to 380
400V class: 660 to 760
0 (disabling the thermistor), 1 (enabling the thermistor
with PTC), 2 (enabling the thermistor with NTC)
0 to 9999
0 to "free-setting V/f frequency (2)"
0 to 8000
0 to "free-setting V/f frequency (3)"
0 to 8000
0 to "free-setting V/f frequency (4)"
0 to 8000
0 to "free-setting V/f frequency (5)"
0 to 8000
0 to "free-setting V/f frequency (6)"
0 to 8000
0 to "free-setting V/f frequency (7)"
0 to 8000
0. to "free-setting V/f frequency (8)"
0 to 8000
0 (disabling), 1 (enabling)
0 to 500
0 to 500
0 to 40000
*6
0 to 40000
8 - 7
Chapter 8 Appendix
Setting during
Updating during
Minimum
operation
operation
unit
(allowed or not)
(allowed or not)
1(%)
1(%)
1(%)
×
1(%)
×
1(%)
×
1(%)
×
×
×
0.01 (Hz)
×
×
0.1 (kHz)
×
×
×
×
0.1
×
×
×
×
×
0.1 (%)
×
×
×
×
1 (V)
×
×
1 (Ω)
×
×
1 (Hz)
×
×
0.1 (V)
×
×
1 (Hz)
×
×
0.1 (V)
×
×
1 (Hz)
×
×
0.1 (V)
×
×
1 (Hz)
×
×
0.1 (V)
×
×
1 (Hz)
×
×
0.1 (V)
×
×
1 (Hz)
×
×
0.1 (V)
×
×
1 (Hz)
×
×
0.1 (V)
×
×
0.01 (s)
×
0.01 (s)
×
0.01 (s)
×
0.01 (s)
×
0.01 (Hz)
×
0.1 (%)
×
0.01 (Hz)