Siemens SINUMERIK 840D sl Function Manual page 167

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

System variable
$SN_PA_CONT_TYP[0,2]
$SN_PA_CONT_TYP[0,3]
$SN_PA_CONT_TYP[0,4]
$SN_PA_CONT_TYP[0,5]
$SN_PA_CONT_TYP[0,6]
$SN_PA_CONT_TYP[0,7]
$SN_PA_CONT_TYP[0,8]
$SN_PA_CONT_TYP[0,9]
$SN_PA_CONT_TYP[1,0]
$SN_PA_CONT_TYP[1,1]
$SN_PA_CONT_TYP[1,2]
$SN_PA_CONT_TYP[1,3]
$SN_PA_CONT_TYP[1,4]
$SN_PA_CONT_TYP[1,5]
$SN_PA_CONT_TYP[1,6]
$SN_PA_CONT_TYP[1,7]
$SN_PA_CONT_TYP[1,8]
$SN_PA_CONT_TYP[1,9]
$SN_PA_CONT_ORD[0,0]
$SN_PA_CONT_ORD[0,1]
$SN_PA_CONT_ORD[0,2]
$SN_PA_CONT_ORD[0,3]
$SN_PA_CONT_ORD[0,4]
Basic Functions
Function Manual, 01/2015, 6FC5397-0BP40-5BA2
Val‐
Remark
ue
1
; Contour type[i] : 1 = G1 for even
; Protection zone for workpiece, contour element 2
1
; Contour type[i] : 1 = G1 for even
; Protection zone for workpiece, contour element 3
1
; Contour type[i] : 1 = G1 for even
; Protection zone for workpiece, contour element 4
0
; Contour type[i] : 0 = not defined
; Protection zone for workpiece, contour element 5
0
; Contour type[i] : 0 = not defined
; Protection zone for workpiece, contour element 6
0
; Contour type[i] : 0 = not defined
; Protection zone for workpiece, contour element 7
0
; Contour type[i] : 0 = not defined
; Protection zone for workpiece, contour element 8
0
; Contour type[i] : 0 = not defined
; Protection zone for workpiece, contour element 9
1
; Contour type[i] : 1 = G1 for even
; Protection zone for toolholder, contour element 0
3
; Contour type[i] : 3 = G3 for circuit element, counter-clockwise
; Protection zone for toolholder, contour element 1
1
; Contour type[i] : 1 = G1 for even
; Protection zone for toolholder, contour element 2
1
; Contour type[i] : 1 = G1 for even
; Protection zone for toolholder, contour element 3
1
; Contour type[i] : 1 = G1 for even
; Protection zone for toolholder, contour element 4
0
; Contour type[i] : 0 = not defined
; Protection zone for toolholder, contour element 5
0
; Contour type[i] : 0 = not defined
; Protection zone for toolholder, contour element 6
0
; Contour type[i] : 0 = not defined
; Protection zone for toolholder, contour element 7
0
; Contour type[i] : 0 = not defined
; Protection zone for toolholder, contour element 8
0
; Contour type[i] : 0 = not defined
; Protection zone for toolholder, contour element 9
-80
; Endpoint of contour[i], ordinate value
; Protection zone for workpiece, contour element 0
-80
; Endpoint of contour[i], ordinate value
; Protection zone for workpiece, contour element 1
80
; Endpoint of contour[i], ordinate value
; Protection zone for workpiece, contour element 2
80
; Endpoint of contour[i], ordinate value
; Protection zone for workpiece, contour element 3
0
; Endpoint of contour[i], ordinate value
; Protection zone for workpiece, contour element 4
A3: Axis Monitoring, Protection Zones
3.5 Examples
167