12/2008
Machine trigger
All actions that are available in the control monitor are initiated with a machine
trigger. Machine triggers are initiated on the basis of either control variables or
events that take place on the control PC.
Please select the required trigger type.
Add machine trigger
Alarm group
PLC trigger
PLC timeout trigger
Trigger on new value of ePS variable
Combined machine trigger: Alarm group and PLC trigger
Error message on the HMI
Time trigger
Add server trigger
A measurement of a series of measurements reaches a limit value
Trigger when maintenance jobs are (over)due
Variable monitor reaches limit value
Cyclic trigger on variable monitor
Fault message on PC

3.4.4 Machine trigger on "alarm group"

Description of functions
The "alarm group" trigger can be used to respond to all alarms programmed in the
control. These alarms also include the user area for alarm numbers that are used
to program the machine functions for machine diagnostics purposes. If machine
diagnostics are not performed on the basis of alarm numbers, there is no option of
linking these error messages here. The alarm numbers that initiate triggers can be
entered individually, in groups or in series.
It is also possible to remove individual alarms or groups from a selection. In
addition to this, conditions that are not meant to initiate a trigger on their own can
be linked (e.g. if a particular alarm is only meant to initiate a trigger in Automatic
mode).