N2000 Bms Server Is Shut Down Automatically Because The Setting Of The Configuration File Of Solaris Os Is Incorrect - Huawei MA5600 Manual

Access network product cases
Table of Contents

Advertisement

MSAN UA5000 Cases
problem is not caused by the N2000 BMS.
3. Log in to the MA5100 manually, and it is found that the system prompts too many users. The
problem is traced to too many accounts that log in to the MA5100 or the user account is
deadlocked. After the users are disconnected automatically by the system, you can log in to the
MA5100 and the MA5100 can be added.
Suggestions and
Null
Summary:
6.6
N2000 BMS Server Is Shut Down Automatically Because the Setting of the
Configuration File of Solaris OS Is Incorrect
Title:
N2000 BMS Server Is Shut Down Automatically Because the Setting of the Configuration
File of Solaris OS Is Incorrect
ID:
SE0000394087
Update Time:
2009-06-02 14:04:12
Author:
h93856
Product Family:
Access Network Management System
Fault Type:
Operation system
Keywords:
Shut down automatically, Solaris
Phenomenon De
The N2000 BMS server is frequently shut down automatically. Then, the server runs in the
scription:
normal state after it is restarted.
Alarm Informat
Null
ion:
Cause Analysi
The possible causes are as follows:
s:
1. The power supply or the hardware is abnormal.
2. The Solaris OS is abnormal.
3. Other settings are incorrect.
Handling Proce
1. Check the hardware and the system when the N2000 BMS server is running and it is found
ss:
that both the hardware and the system are normal. That is, no alarm is reported, and the CPU
usage and memory usage rates are low.
2. Test the power supply on site and it is found that the power supply is normal. The fault may
be caused by incorrect setting of the configuration file.
3. Run the power.conf file and the following message is found:
root@N2000Server # more /etc/power.conf
device-dependency-property removable-media /dev/fb
autopm default
statefile //.CPR
# Auto-Shutdown
autoshutdown
As shown in the preceding message, by default, the N2000 BMS server is automatically shut
down after the system retains idle for 30 minutes. The cause of the fault is found.
4. Change the default value to noshutdown and then restart the system. Then the N2000 BMS
server runs in the normal state and is not shut down automatically.
Suggestions and
Null
Summary:
Confidential Information of Huawei. No Spreading without Permission
Product:
Idle(min)
Start/Finish(hh:mm)
30
9:00 9:00
Chapter 6 iManager N2000 BMS Cases