4. The BMS version is N2000 BMS V200R011C02C026 and the server version is SUN Server
V890.
Alarm Informat
Null
ion:
Cause Analysi
The onsite information is as follows:
s:
1. In the standalone mode, both server A and server B work in the normal state.
2. The IP addresses of server A and server B are 10.101.2.205/24 and 10.101.2.206/24. Only
one network port works on each server.
3. Run the WatchmanExplorerV1R2_conf.sh script in the /opt/watchman/server/bin directory to
collect fault information. The fault information file is placed in the /tmp directory.
Note: The WatchmanExplorerV1R2_conf.sh is a new tool on the N2000 BMS
V200R011C02C026 for collecting fault information.
Handling Proce
1. After analyzing the fault information file that is generated by the
ss:
WatchmanExplorerV1R2_conf.sh, R&D engineers confirm that the replication process and
configuration on server A and server B are normal.
2. After the Quick Recover function of the Watchman is enabled on site, the replication relation
between the active server and the standby server returns to normal. The problem is solved.
Suggestions and
The configuration and operation interface of the Watchman on the N2000 BMS
Summary:
V200R008B02D061 are greatly different from those on the N2000 BMS V200R011C02C026.
Pay attention to the differences when using different BMS versions.
6.11 GPON ONT terminal upgrade function isn't available on BMS N2000
Title:
GPON ONT terminal upgrade function isn't available on BMS N2000
ID:
SE0000348010
Update Time:
2008-09-26 09:59:02
Author:
Lin Yanhua
Product Family:
Access Network Management System
Fault Type:
Service Management
Keywords:
GPON ONT Upgrade BMS
Phenomenon Des
ONT upgrade funciont is new feature of BMS,but I have failed serveral times to upgrade Ont on BMS.
cription:
please referto "upgrade terminal isn't available.jpg"
Alarm Informati
null
on:
Cause Analysi
1.BMS running abnormally
s:
2.The ONT don't support terminal upgrade funciotn by BMS
not all ONT can support the remote upgrade by BMS.
only some type of ONT produced by Huawei or the ONT has been bested by Huawei.
Handling Proces
1.Check the BMS xPON processing, it's running normally.
s:
check the ONT work normally through the CLI command method.
2.BMS can manage and config OLT and ONT normally. all other function is normal except for Upgrade terminal.
3. Change the configuration about the ONT vendor, ONT type, ONT software on N2000.
Click the menu "modify", then configure correct VendorID, Terminal Type,Softwareversion etc.
please refer to "select the correct ONU information.jpg"
4. Check and test again, the "Upgrade terminal" menu become normal.
please refer to "Upgrade Terminal is available.jpg"
Suggestions and
null
Summary: