Technical Specifications
General
Dimensions (w x h x d)
Weight
Line voltage external power supply
Line voltage frequency
Brief voltage interruption acc. to Namur
Max. power consumption
Output DC voltage (external power supply)
Output DC current (external power supply)
Output DC power (external power supply)
Standby power ( battery operation)
Lithium Ion rechargeable battery (9 cells)
with charge-status monitoring
Degree of protection
Quality assurance
Safety
Requirements
Noise emission
Electromagnetic compatibility (EMC)
Emitted interference
Line-fed interference on AC supply lines
Noise immunity on signal lines
Noise immunity to discharges of static
electricity
Immunity to RF interference
Magnetic field
B-2
328 x 294 x 52 mm
approx. 4 kg
100 VAC to 240 VAC (+ 10% / – 15%), sinusoidal
50 / 60 Hz (47 to 63 Hz)
> 20 ms at 93 V (AC power supply)
(max. 10 times per hour; min. recovery time 1 s)
90 W
18.5 V
max. 4.3 A
max. 80 W
typ 1.5 W
approx. 6 Ah, 11.1 V with thermostatic switch and multifuse,
recyclable, chargeable up to 40°C (108° F), high number of
charge cycles under severe conditions, low self-discharge
rate
IP30 (covers closed)
ISO 9001
VDE 0805 ^ EN 60950 and IEC 60950
Protection class I to IEC 60536
Protective separation between supply and secondary circuit
(via external power supply)
<45 dB(A) to DIN 45635
limit value class B to EN 55022, EN 6100–3–2,
"2 kV (IEC 61000-4-4; burst)
"1 kV (IEC 61000-4-5; ms pulse/line to line)
"2 kV (IEC 61000-4-5; ms pulse/line to ground)
"2 kV (IEC 61000-4-4; burst; length >3 m)
"2 kV (IEC 61000-4-5; ms pulse/line to ground;
length > 20 m)
"4kV, Contact discharge (IEC 61000-4-2; ESD)
"8kV, Air discharge (IEC 61000-4-2; ESD)
10 V/m, with 80% amplitude modulation at 1 kHz,
9 kHz - 80 MHz (to IEC 61000-4-6)
10 V/m with 80% amplitude modulation at 1 kHz,
80 kHz - 1GHz (to IEC 61000-4-3)
10 V/m, pulse modulated 50% duty cycle, 900MHz and
1,89 GHz (to IEC 61000-4-3)
30 A/m, 50Hz (to IEC 61000-4-8)