MPI/DP
Pinout of the MPI/DP socket:
Pin No.
Designation
1
-
2
-
3
LTG_B
4
RTS_AS
5
M5EXT
6
P5 EXT
7
-
8
LTG_A
9
RTS_PG
Screen
SIMATIC Field PG P4 Manual
A5E00180080-04
1
5
6
9
Description
Unassigned
Unassigned
Signal line B of MPI module
RTSAS, control signal for received data
stream. The signal is "1" active when the
directly connected programmable controller is
sending.
M5EXT return line (GND) of the 5 V power
supply. The current load caused by an
external user connected between P5EXT and
M5EXT must not exceed the maximum of
90 mA.
P5EXT power supply (+5 V) of the 5 V power
supply. The current load caused by an
external user connected between P5EXT and
M5EXT must not exceed the maximum of
90 mA.
Unassigned
Signal line A of the MPI module
RTS output signal of the MPI module. The
control signal is "1" when the programming
device is sending.
on connector casing
Hardware Information
Input/Output
-
-
Input/output
Input
Output
Output
-
Input/output
Output
7-5