Siemens M20 Terminal Technical Description page 122

Cellular engine
Hide thumbs Also See for M20 Terminal:
Table of Contents

Advertisement

Siemens Information and Communication Products
AT^SMSO
Switch off mobile station turn off
Test command
Response
AT^SMSO=?
OK
Execute command
Response
AT^SMSO
Device switches off immediately (max. deactivation time 1.5 s–6 s)
OK
Note1: the IGNITION signal is checked every 100 ms. If the signal goes LOW, another two checks
are performed at 100 ms intervals to ascertain whether the signal remains LOW. If it does, the shut-
down sequence is initiated (for details, see "AT^SMSO"). If the two additional checks show that
the signal is no longer LOW, the checks sequence restarts.
Note2:
Parameter
Reference
Note
AT^SNFA
Set or query of microphone attenuation
Test command
Response
AT^SNFA=?
^SNFA: (list of supported <atten>s) OK
Parameter
see set command
Read command
Response
AT^SNFA?
TA returns the attenuation value.
Note: if microphone is muted, TA returns value 0.
^SNFA: <atten> OK
Parameter
see set command
Set command
Response
AT^SNFA=
TA controls the large-scale attenuation on the microphone path.
<atten>
Note: if microphone is muted, set is disabled.
OK
Parameter
<atten>
Reference
Note
GSM Engine A1
Value 0 can be set only by AT^SNFM=0
Version 8 dated 15.03.00
if signal of connector 1 is set to low = device is switched off.
attenuation/dB = 20*log (<atten> /16384
0 (0x0) – 65535 (0xFFFF)