Siemens M20 Terminal Technical Description page 41

Cellular engine
Hide thumbs Also See for M20 Terminal:
Table of Contents

Advertisement

Siemens Information and Communication Products
ATS4
Set response formatting character
Read command
Response
ATS4?
<n> OK
Set command
Response
ATS4=<n>
This parameter setting determines the character generated by the TA for result code and informati-
on text.
OK
Parameter
<n>
Note:
Reference
Note
V.25ter
ATS5
Set command line editing character
Read command
Response
ATS5?
<n> OK
Set command
Response
ATS5=<n>
This parameter setting determines the character recognized by TA as a request to delete the imme-
diately preceding character from the command line.
OK
Parameter
<n>
Note:
Reference
Note
V.25ter
ATS7
Set number of seconds to wait for connection completion
Read command
Response
ATS7?
<n> OK
Set command
Response
ATS7=<n>
This parameter setting determines the amount of time to wait for connection completion when ans-
wering or originating a call.
OK
Parameter
<n>
Reference
Note
V.25ter
ATS8
Set number of seconds to wait when comma dial modifier
Read command
Response
ATS8?
<n> OK
Set command
Response
ATS8=<n>
No effect at GSM
OK
Parameter
<n>
Reference
Note
V.25ter
Version 8 dated 15.03.00
0-10-127
default 10 = LF
0-8-127
default 8 = backspace
0-60-255 number of seconds to wait for connection completion
0
no pause when comma encountered in dial string
2
Default value
1-255 number of seconds to wait
response formatting character
command line editing character
AT command interface
A
41

Hide quick links:

Advertisement

Table of Contents
loading