Chapter 3 Programming Your Counter for Remote Operation
Status Reporting
Standard Event Status Register Group
Standard Event
Enable Register
0
1
2
3
4
5
6
7
Figure 3-12. Standard Event Status Reporting
Standard Event Status Register
The Standard Event Status Register contains bits that monitor specific
IEEE 488.2-defined events as shown in Figure 3-12.
Use *ESR? to read this register.
Use *ESR? or *CLS to clear this register.
Table 3-5 lists the Standard Event Status Register bits and briefly describes
each bit.
3-30
&
&
&
&
&
&
&
&
Logical OR
Standard Event
Status Register
0
Operation Complete
1
Not Used
2
Query Error
3
Device-Dependent Error
4
Execution Error
5
Command Error
6
Not Used
7
Power On
To ESB bit (bit 5) of the
Status Byte Register