2.

IF YOU REPLACE THE CIS UNIT

Note:
• Replace the first side or second side CIS unit so that both of them are new or old. If the
old CIS unit was replaced with the new one, update the firmware with the latest version.
New CIS unit does not work with the old firmware.
Refer to
"How to determine whether CIS is new or
<What to do after replacement>

• Checking firmware version

• CIS type setting
• Installing firmware
• Acquiring white level data
• Checking operation after repair
2.1
Checking Firmware Version
Check whether the firmware installed on the main PCB is the D version or later. If it is the D
version or later, there is no need to install the firmware. If it is not, be sure to install the firmware
to the main PCB as described in
<How to check firmware version>
(1) Press and hold the
state. LEDs except WiFi LED light.
(2) Press the [to USB], [to Network Device2], and [to Network Device1] keys in this order. The
to USB, Error,
(3) Press the [to Network Device2] key. All LEDs go out.
(4) Press the [to Network Device2] key again. The to Network Device2 LED lights.
(5) Press the
(6) Turn ON the computer.
(7) Connect the computer to the machine with the USB cable.
(8) Double-click "brmfrmss.exe" that was copied into the temporary folder to start remote
check mode. The screen shown below appears.
(9) Click the [Machine Info.] tab. The firmware version is displayed.
"2.3 Installing Firmware"
key for five seconds or longer when the machine is in the ready
, and
LEDs light and the machine enters the maintenance mode.
key.
old".
in this chapter.