Section 2 System Specifications; General Precautions; Environmental Requirements; Operating Conditions - NEC SL1100 Hardware Manual

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

SL1100

SECTION 2 SYSTEM SPECIFICATIONS

2.1

General Precautions

Never attempt to insert wires, pins, etc. into the vents or other holes of the equipment.
Do not use benzene, thinner, or the like, or any abrasive powder to clean the equipment. Wipe it
with a soft cloth.
2.2

Environmental Requirements

Meeting established environmental standards maximizes the life of the system. Be sure that the site is
not:
In direct sunlight or in hot, cold or humid places.
In dusty areas or in areas where sulfuric gases are produced.
In places where shocks or vibrations are frequent or strong.
In places where water or other fluids comes in contact with the equipment.
In areas near high-frequency machines or electric welders.
Near computers, telexes, microwaves, air conditioners, etc.
Near radio antennas (including shortwave)
2.3

Operating Conditions

Unit
KSU, PCBs and Multiline Telephones
Doorphone Box
2.4

Site Requirements

A KSU can only be wall-mounted, it can only be floor-mounted if the optional External Backup Battery
Box is installed.
2.5

AC Power Requirement

A dedicated 100V-120V/220V/230V/240V 50/60Hz circuit located within 2 meters of the KSU is
required. A separate dedicated AC outlet is necessary for the KSU.
Double Pole/Neutral Fusing
(Power supply fuses are located at both the L and N side.)
Power Requirement
Power Consumption
Input Voltage (Rated Voltage)
Frequency
Phase and Wire
Ground Requirement
Feeding Voltage
5-2

Table 5-2 Operating Conditions

Temperature: 0 to +40 degree C (32 to 104 degree F)
Humidity: 10 to 90% (non-condensing)
Temperature: -20 to +60 degree C (-4 to 140 degree F)
Humidity: 20 to 80% (non-condensing)

Table 5-3 Power Requirement

110VAC
120VAC
110
120
VAC@15 A
VAC@15 A
Main KSU =
Main KSU =
128 VA
130VA
90 VAC to 264 VAC (100VAC/120VAC/220VAC/230VAC/240VAC)
47 Hz - 63 Hz (Rated Frequency: 50/60 Hz)
Single Phase, 2 Line + PE Type
Operating Conditions
220VAC
230VAC
220
VAC@15 A
VAC@15 A
Main KSU =
Main KSU =
154 VA
154 VA
No.14 AWG Copper Wire
SLT: 20 mA/-27 V
ISSUE 1.0
240VAC
230
240
VAC@15 A
Main KSU =
156 VA
Specifications