SL1100
Switch No.
J13, J14/J16, J17
J12 & J15 do not configure the connection type on the system, they only add/remove the termination of the
circuit.
J13,J14 & J16, J17 do not configure the connection type on the system, they only select the polarity of
the connector J2/J3. The 2BRIDB-C1 circuits must also be setup within the system configuration.
2.
Connect the cables from the NT1 Network Termination cable to the J2 or J3 connector on the
2BRIDB-C1 daughter board.
Connector J2 - BRI1: Use switches J12, J13, J14
Connector J3 - BRI2: Use switches J15, J16, J17
Ensure that you set all switches correctly for each BRI circuit.
3.4.6
Cabling and Setting IP4WW-1PRIU-C1
This IP4WW-1PRIU-C1 PCB provides one RJ-45 PRI connection.
2-46
Switch Position
OFF
P-MP (Terminal 7)
T (default)
T-Bus connection
S
S-Bus connection
Figure 2-72 Switches Location of 2BRIDB-C1
Description
T-Bus Point-to-Multipoint is selected, and if the system is
Terminal 8. (last device on the bus)
S-Bus.