Toshiba 2000 V Series Manual page 68

Integrated controller module
Hide thumbs Also See for 2000 V Series:
Table of Contents

Advertisement

Chapter 3 Preparations for Operation (Hardware)
3
46
(1) Thick Cable (for trunk line)
Manufacturer: Rockwell Automation
Item name
1 m with connectors
1485C-P1N5-M5
2 m with connectors
1485C-P2N5-M5
3 m with connectors
1485C-P3N5-M5
5 m with connectors
1485C-P5N5-M5
10 m with connectors
1485C-P10N5-M5
50 m without connector
1485C-P1-A50
150 m without connector
1485C-P1-A150
300 m without connector
1485C-P1-A300
(2) Thin Cable (for trunk line and drop line)
Manufacturer: Rockwell Automation
Item name
1 m with connectors
1485R-P1M5-C
2 m with connectors
1485R-P2M5-C
3 m with connectors
1485R-P3M5-C
150 m without connector
1485C-P1-C150
300 m without connector
1485C-P1-C300
600 m without connector
1485C-P1-C600
(3) Tap/Multiport Tap
Manufacturer: Rockwell Automation
Item name
T-Port Tap
DeviceBox Tap (2 ports)
DeviceBox Tap (4 ports)
DeviceBox Tap (8 ports)
(4) Others
Manufacturer: Rockwell Automation
Item name
PowerTap
Terminator (male)
Terminator (female)
Catalog No.
1485C-P1N5-M5 Shielded mini-connectors
(male, female) attached
Shielded mini-connector (male) at one end,
shielded mini-connector (female) at the other
end
Shielded mini-connectors, 871A-TS5-NM3
(male) and 871A-Ts5-N3 (female) to be
attached later
Catalog No.
Shielded mini-connector (male) at one end
and a discrete end at the other for open-type
connector
Used for daisy-chain connection from one
open-type connector to another. Used for
connecting DeviceBox Tap to an open-type
connector
Catalog No.
1485P-P1N5-MN5R1
T-branch (one drop line from the trunk
line) Connect cables with shielded mini-
connectors for both trunk and drop lines.
1485P-P2T5-T5
2 drop lines from the trunk line
1485P-P4T5-T5
4 drop lines from the trunk line
1485P-P8T5-T5
8 drop lines from the trunk line
The trunk line and drop line cables
connected to a DeviceBox tap have a
discrete end for open-type connectors.
Catalog No.
1485T-P2T5-T5
Tap power capacity of 7.5 A to supply
power to trunk lines.
The trunk line with overcurrrent
protection to be connected to a power
tap has a discrete end for open-type
connector, instead of shielded mini-
connector).
1485A-T1M5
To terminate the trunk line. Used for a
thick cable with mini-connector or T-Port
1485A-T1N5
tap.
model 2000 DeviceNet Module Manual (DN611/DN611A)
Remarks
Remarks
Remarks
Remarks

Advertisement

Table of Contents
loading

This manual is also suitable for:

Devicenet dn611Devicenet dn611a

Table of Contents