OPERATION
3-58
Step
7
Press the "3" key and "Enter" key, then, following menu is
displayed,
For 1+0 System
Monitoring
1.
Monitoring voltage
2.
Monitoring voltage (Continuance mode)
3.
Alarm/Status
4.
Inventory
00. Menu
99. Exit
Select item No. :
For 1+1 System
Monitoring
1.
Monitoring voltage
2.
Alarm/Status
3.
Inventory
00. Menu
99. Exit
Select item No. :
8
Press the "1" key and "Enter" key, then, following item is
displayed,
Note: The voltages shall be indicated within the values shown in
Table 3-4 in normal,
For 1+0 System
1. Monitoring voltage
Transmitter power
Receiving level
For 1+1 System
1.
Monitoring voltage
Transmitter power 1
Receiving level 1
Transmitter power 2
Receiving level 2
Procedure
: 4.33V (-1 dB)
: 3.55V (-32 dBm)
: 4.33V (-1 dB)
: 2.98V (-46 dBm)
: 4.33V (-1 dB)
: 2.18V (-66 dBm)