Equipment Setting And Monitoring - NEC PASOLINK Training Course

Digital microwave radio system
Table of Contents

Advertisement

OPERATION
3.3.2 Shut-down

3.4 Equipment Setting and Monitoring

3-30
Step
1
Turn off the POWER switch on the front of the IDU.
Note: In 1+1 system, before turn off the POWER switch of No.1
or No. 2 channel, check that the OPR SEL No.1 - No.2
switch is set to channel position to be working.
Test Equipment and Accessories Required
• Personal Computor
• RS-232C cable
• Screw Driver
The control of the IDU and ODU digital radio system can be carried out
via the LA PORT or NMS/RA of the IDU. Connect a Personal Computer
to the IDU with an RS-232C cable. The specifications of the required
communication port condition of the personal computer are listed below.
• Baud rate :
• Data Length :
• Parity Check :
• Stop bit :
• Flow control:
• Emulation :
• Transmission:
MS Hyper
Terminal*:
• Receiving:
Notes: 1. MS : Microsoft
* For Windows 95/98/Me/NT4.0/2000/XP
2. When Windows NT4.0 and MS hyper terminal is used,
"Program Download" function is not available.
In this case, please use other terminal software.
(e.g. TeraTerm Pro 2.3:
http://hp.vector.co.jp/authors/VA002416/teraterm.html)
Procedure
9600
8
None
2
None
VT100 Video Terminal
Send line ends with line feeds : Yes
Local echo : No
CR : No
Return on the right edge : Yes
Force incoming data to 7-bit ASCII : No