NEC PASOLINK Training Course page 110

Digital microwave radio system
Table of Contents

Advertisement

ROI-S04488
CHECK ITEM
Transmitter power
Receiving level
Step
9
Press the "Esc" key to go back to the Monitoring menu, then,
enter 99 to exit the monitoring of the Pasolink.
For 1+0 System
Monitoring
1.
Monitoring voltage
2.
Monitoring voltage (Continuance mode)
3.
Alarm/Status
4.
Inventory
00. Menu
99. Exit
Select item No. :
For 1+1 System
Monitoring
1.
Monitoring voltage
2.
Alarm/Status
3.
Inventory
00. Menu
99. Exit
Select item No. :
Table 3-4 Meter Reading of IDU and ODU
Depends on transmitter power
• 0 to 4.6 V DC (Bit rate free type ODU*1)
• 0 to 4.6 V DC (Fixed bit rate type 7/8 GHz ODU*2)
Depends on received signal level
• 0.8 to 4.4 V DC (Bit rate free type ODU*1)
• 0.8 to 4.4V DC (Fixed bit rate type 7/8 GHz ODU*2)
Notes:1. *1 The code number of bit rate free type ODUs are as follows:
• G2924
• G5384
• H0330
• H0334
2. *2 The code number of fixed bit rate type 7/8 GHz ODUs are
as follows:
• G6583
• H0738
Procedure
ALLOWABLE RANGE
• G3359
• G5380
• G6594
• H0331
• H0332
• H0335
• G6584
• G6585
• H0739
OPERATION
• G5383
• H0333
• G6586
3-59

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents