Setting①: Initial Setting Select-1 - Mitsubishi Electric KD Series User Manual

Contact image sensor, web surface inspection
Hide thumbs Also See for KD Series:
Table of Contents

Advertisement

5-2 Setting①: Initial setting select-1
Address
Register name
7200h UserSet_1_Save
7204h UserSet_2_Save
7208h UserSet_3_Save
720Ch UserSet_1_Load
7210h UserSet_2_Load
7214h UserSet_3_Load
UserSet_Load_
7218h
FactoryDefalut
7240h
UserSet_BootSet_
select
7244h
UserSet_Boot_Error
5-2-3 Initial Setting Select-1
[Function]
Save and read CIS Initial Setting
After power ON, this product boots an Initial Setting which is
selected by the value of "UserSet_BootSet_select".
By running a function of "UserSet_#_Save", the active CIS settings
can be saved on a Flash Memory on this product. (For example,
values of CIS Setting, White/Dark Correction, and γ Correction.)
Correction data for 600dpi can be saved in initial setting. If setting
the correction data for other resolution, please refer to next page.
You can save 3 different User Settings (from 1 to 3).
By running a function of "UserSet_#_Load", this product booth the
selected User Setting.
TM-XJ959A
R/W
Parameter
Data
R/W
1
Save CIS settings to User Setting 1 on Flash Memory.
R/W
1
Save CIS settings to User Setting 2 on Flash Memory.
R/W
1
Save CIS settings to User Setting 3 on Flash Memory.
R/W
1
Read out CIS settings on User Setting 1.
R/W
1
Read out CIS settings on User Setting 2.
R/W
1
Read out CIS settings on User Setting 3.
R/W
1
Read out CIS settings on Factory Setting (Initial Setting).
R/W
0 to 3
Select a setting to boot after power-ON.
0:Factory Setting, 1:User Setting 1, 2:User Setting 2, 3:User setting 3
Error flag of booting CIS
R
0 to 7
'0' or '1' at bit0 :normal operation, '1' at bit1 :Error of User setting value,
'1' at bit2 :Error of FPGA starting.
Camera Link® is a trade mark registered by AIA(Automated Imaging Association).
Function
[Remark]
1)Never turn off the product while UserSet _ # _ Save is
running. This product may be not able to operate normally
due to break setting data for saving.
It takes about 30 seconds to complete to save all data.
When this product detect to break the user setting data
automatically, factory setting is loaded instead of user
setting data when turn on this product.
2)If changing the resolution, please execute
UserSet_Use_###dpi command shown in next page prior
to save white/dark correction data.
Initial
-
-
-
-
-
-
-
0
-
68
© Mitsubishi Electric Corporation

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kd6r1064dxl-nlKd6r1247dxl-nlKd6r1688dxl-nl

Table of Contents